Germicidal Lamp Monitor

GLM10 Germicidal Lamp Monitor

Solar Light’s GLM10 Germicidal Lamp Monitor is specifically designed to continuously monitor germicidal lamp output in water contact vessels.

GET A QUOTE

Description

Ultraviolet Disinfection System Monitor
Ultraviolet water disinfection systems are only as good as the effectiveness of the germicidal lamps. With time, even the best UV water treatment system will show a significant degradation in its ability to disinfect water. Germicidal lamp output decreases as the lamp ages and /or becomes dirty through use.

Solar Light’s GLM10 Germicidal Lamp Monitor is specifically designed to continuously monitor germicidal lamp output in water contact vessels. The GLM10 assures that the germicidal lamp output stays within the manufacturer’s specifications for effective and safe water disinfection. The unit screws into the service port of an exposure chamber, where the built-in UV sensing probe monitors the lamp. The GLM10 is easily calibrated to 100% when a new lamp is installed and displays 0 – 100% intensity values. As the lamp ages and the output drops, the display accurately shows the intensity level as a percentage of initial lamp intensity. A preset threshold is used to determine when the threshold is reached, and then both the fault light and internal relay are activated for automatic valve control or remote alarm, ensuring a continuous supply of safe drinking water.

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

1.5lbs (0.68kg)

This field can't be Empty

4 5/8" x 3 1/8" x 5" (11.7 x 7.9 x 12.7 cm)

This field can't be Empty

Brochure

GLM10 Germicidal Lamp Monitor

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.