1.2" (3 cm) 150W General Purpose Air Mass 1.5 Solar Simulator Kit Model 16S-150-007 - Solarlight

1.2″ (3 cm) 150W General Purpose Air Mass 1.5 Solar Simulator Kit Model 16S-150-007

The 150W Model 16S-150-007 is a general purpose, low cost Air Mass 1.5 ready simulator which can also be configured for UVB only, UVA+B, Visible, or custom spectra optionally by adding the required optical components.

GET A QUOTE

Description

Solar Light’s Model 16S-150-007 is a general purpose, entry level Xenon Arc testing kit.

This unit has all of the filters, mirrors, and collimating lenses required for a Class A Spectrum simulator, except the Air Mass Filter set, which can be purchased and installed by the user at a later time. It can also be configured for UVA only, UVB only, UVA+B, Visible, or custom spectra optionally by adding the required optical components. Output can be controlled from 70-100% via the included XPS-150 power supply. The unit has a 1.2″ (3 cm) round horizontal output as standard, but may also be used with our optional vertical adapter.

General purpose irradiation, scientific research, and materials testing.

This field can't be Empty

Optional On All Models

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (please specify at order)

This field can't be Empty

±10%

This field can't be Empty

N/A

This field can't be Empty

Forced air

This field can't be Empty

Xenon Short Arc

This field can't be Empty

< ±2% rms

This field can't be Empty

Near Zero

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

32°F to 95°F / 0°C to +35°C

This field can't be Empty

1.2” (3 cm)

This field can't be Empty

Factory Set Limit is 150 watts

This field can't be Empty

Optional On All Models

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

7.7 lbs. (3.2 kg.)

This field can't be Empty

3.9” (10 cm)

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

150W

This field can't be Empty

<ul> <li><a href=https://solarlight.com/product_category/solar-simulators/16s-series-air-mass-simulators/>16S-150-AM Air Mass 1.5 Ready Solar Simulator with 1.2” (3 cm) horizontal output</a></li> <li><a href=https://solarlight.com/product/xps-150-xenon-lamp-power-supply/>XPS-150 Power Supply</a></li> <li><a href="https://solarlight.com/product/sl-07702-dark-safety-glasses/">UV Safety Glasses (Dark)</a></li> </ul>

This field can't be Empty

1.2” (3 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to +35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

7.7 lbs. (3.2 kg.)

This field can't be Empty

Brochure

Basic Academic Research Testing 16S-150-007

Quick Start Guide

16S-Series 150-300W Solar Simulator Quick Start Guide

SL-06173 150 Watt Ozone-Free Short Arc Xenon Lamp

This OEM Xe Replacement Lamp is designed to work with current Solar Light 16-Series 150W Solar Simulators, as well...

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.