P2 Certified Formula - Solarlight

P2 Certified Formula

Solar Light Company offers a full selection of Pre-Analyzed and Certified Sunscreen Standards for laboratory use including P2 Certified Formula, P5 SPF 30 Reference Standard, P8 High Reference Standard, S1 UVA Reference Standard, and S2 UVA Reference Standard. Each batch will include a Certificate of Analysis for Homosalate content. Our batches have passed preservative challenge testing and have shown stable Homosalate content, microbiological integrity, and emulsion stability for at least one year.

 

GET A QUOTE

Description

Solar Light Company offers a full selection of Pre-Analyzed and Certified Sunscreen Standards for laboratory use.

These include:

SPF Standards

  • P2 Certified Formula
  • P5 SPF 30 Reference Standard
  • P8 High Reference Standard

UVA Standards

  • S1 UVA Reference Standard
  • S2 UVA Reference Standard

Standards are available in either 2 oz. or 1 oz. containers.

Each batch will include a Certificate of Analysis for Homosalate content. Our batches have passed preservative challenge testing and have shown stable Homosalate content, microbiological integrity, and emulsion stability for at least one year.

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field