PK2122-2G-10 Dual-Input Radiometer Kit - Solarlight

PK2122-2G-10 Dual-Input Radiometer Kit

The PK2122-2G-10 Dual-Input Radiometer Kit includes a PMA2100 Handheld, Data Logging Radiometer and 2 UVC (Extended Range) Germicidal Sensors with 10 m Cable.

GET A QUOTE

Description

The decontamination of personal protective equipment (PPE) requires accurate determination of UVC dose. With PMA UVC germicidal sensors from Solar Light Company, LLC, you can determine the exact UVC dose reaching the PPE from outside the room. Full data logging capabilities and alarm set-points are available for up to 2-channels.

PMA 2100 Dual-Input Radiometer

  • Measures UVC Dose and Intensity 
  • Manual or Automatic Data Logging 
  • 2-Channels 
  • Measures 0-2,000 μW/cm2 or 20,000 μW/cm2 UVC Intensity
  • NIST-Traceable Calibration
  • Made in USA

Kit Includes:

  • PMA2100 Handheld Radiometer
  • 2 x PMA 2122G-10 UVC Germicidal Sensor (UVC Intensity Range 0-20,000 uW/cm2) with 10m Cable
  • Universal Power Supply
  • Rechargeable Battery
  • Battery Charger
  • PMA Organizer Software (Software is listed under ‘Literature and Downloads’ Tab)
  • Carry Case
  • NIST Certificate

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

18 oz. (510 grams)

This field can't be Empty

2 Sockets with Up to 2 Analog Signals Each

This field can't be Empty

±0.4V, ±4V, Auto Ranging

This field can't be Empty

15μV on 0.4V Range

This field can't be Empty

>2x10^5

This field can't be Empty

0.5% FS All Ranges

This field can't be Empty

32 to 120°F (0 to +50°C)

This field can't be Empty

Max 50ppm/°C

This field can't be Empty

4 x AA NiCd or Alkaline Batteries, 9-12V AC or DC Charger

This field can't be Empty

Up to 40 Hours Between Charges

This field can't be Empty

RS-232 Serial Interface and Opto-Isolated Digital I/O

This field can't be Empty

12-Button Keypad

This field can't be Empty

4” x 1.75” x 7.5” (10 x 4.3 x 19.2 cm)

This field can't be Empty

2.25” x 1.25” (5.7 x 3 cm)

This field can't be Empty

18 oz. (510 grams)

This field can't be Empty

<sup>1</sup> The biological effects of UV-A radiation - Edited by F. Urbach and R.W. Gange, Praeger Publishers, New York, 1986 <br> <sup>2</sup> Nichodemus F., “Self study manual on optical radiation measurements”, NBS Technical Note 910-1 (1976).

This field can't be Empty

UVGI Brochure

Ultraviolet Germicidal Irradiation (UVGI) Brochure

PMA Organizer Software

PMA2100 Brochure

Model PMA2100 Data Logging Radiometer Data Sheet

Quick Start Guide

PMA2100 Quick Start Guide

User Manual

Model PMA2100 Data Logging Radiometer User Manual

Choosing A Radiometer