The PMA 2165 thermocouple probe, J type, K type

Model PMA2166 Digital Thermocouple Probe

Solar Light’s Model PMA2166 Digital Thermocouple Probe is available in a K type thermocouple element, which is plugged into a socket mounted on an easy to hold plastic handle. The socket accepts both standard OST and subminiature SMP probes. The PMA2166 can be used with any thermocouple of the designated type.

Category:

Description

Solar Light’s Model PMA2166 Digital Thermocouple Probe is available in a K type thermocouple element, which is plugged into a socket mounted on an easy to hold plastic handle. The socket accepts both standard OST and subminiature SMP probes. The PMA2166 can be used with any thermocouple of the designated type. The thermocouple element is sealed in a stainless-steel envelope forming an 8” (23 cm) long insertion probe, and its operation is based on the Seebeck effect. In general, this function is non-linear. The Seebeck coefficient in microVolts/°C is temperature-dependent. Knowing this function and the voltage generated by the thermocouple, a temperature differential can be calculated. In order to know the absolute temperature of one of the junctions, the temperature of the other one has to be known. The PMA2166’s reference junction is thermally coupled with a calibrated semiconductor temperature transducer that generates a signal proportional to the temperature. Solar Light’s Model PMA2100 Dual-Input Data Logging Radiometer calculates the thermocouple temperature differential and adds it to the reference junction temperature.

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

10 oz. (280 grams)

This field can't be Empty

<ul> <li>Laboratory and Industrial Measurements</li> <li>Environmental Monitoring</li> <li>Metallurgy</li> <li>Heating and Air-Conditioning</li> <li>Agriculture</li> </ul>

This field can't be Empty

-200-1260°C (-330-2300°F)

This field can't be Empty

±2°C

This field can't be Empty

Better than 0.1% per year

This field can't be Empty

This field can't be Empty

°F, °C, K

This field can't be Empty

<strong>Handle:</strong> 1.5" (38.1 mm) <br> <strong>Sensor:</strong> 0.125" (3.18mm)

This field can't be Empty

10 oz. (280 grams)

This field can't be Empty

5ft (1.5 m)

This field can't be Empty

Brochure

Digital Thermocouple Probe PMA2166

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.