UVA + UVB Sensor, Non-Weighted, PMA 1107

Model 501 UVA+B Radiometer

Solar Light’s Model 501 Series Radiometers are rugged meteorological-grade instruments which measure UVA+B solar radiation outdoors and underwater (up to 16.4 feet / 5 meters maximum depth.)

GET A QUOTE

Description

Solar Light’s Model 501 Series Radiometers are rugged meteorological-grade instruments which measure solar radiation outdoors and underwater (up to 16.4 feet / 5 meters maximum depth.) World Class manufacturing practices and NIST traceable calibrations ensure a high degree of reproducibility and comparability from unit to unit. Large networks of these precision devices are relied upon by many of the world’s most prestigious meteorological observatories, weather stations, and research agencies worldwide, such as the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA)  and the Natural Resource Ecology Laboratory (NREL.) Digital versions are available with Sensor Recorders, and analog versions are available with output voltage which is proportional to the measured UV solar radiation. In addition, all 501s feature controlled internal temperature to ensure the highest levels of accuracy.

<ul> <li>This permanent outdoor UVA+B solar radiation measurements system is used in weather stations and meteorological observatories worldwide.</li> <li> Measurement of solar ultraviolet radiation and from artificial sources with wavelengths above 280nm to 400nm. </il> <li>Plant, marine, climatological ozone or other biological impact studies that require continuous field measurements over long periods of time.</li> <li> Measurements for media and research organizations that provide public information about the effects of UV radiation.</li> </ul>

This field can't be Empty

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

2 lbs (0.9Kg)(without cable)

This field can't be Empty

<img src="https://solarlight.com/wp-content/uploads/PMA2107.jpg"><border="0">

<img src="https://solarlight.com/wp-content/uploads/PMA2107-log.jpg"><border="0">

0-10 MED/Hr

This field can't be Empty

Within 5% of Ideal Cosine

This field can't be Empty

1 Second (0.1 second on demand)

This field can't be Empty

1% per C

This field can't be Empty

+/-5%

This field can't be Empty

-40 to 120 °F (-40 to 50 °C)

This field can't be Empty

5.5” x 5.9” (14 x 15 cm)

This field can't be Empty

2 lbs (0.9Kg)(without cable)

This field can't be Empty

Hermetic Connector, 50’ std., Up to 200’ Option, 0.1lb/ft2

This field can't be Empty

3 Leveling Feet, Circular Level

This field can't be Empty

0-2.5V,0.25[V/(MED/hr)], 0.5mA/hr

This field can't be Empty

0-1V, 1V=25 C, Sensitivity 20mV/ C, 0.5mA max

This field can't be Empty

5.5-25V/5mA Max for Signal Circuit. 11-15V/1A Max for Temp Stability

This field can't be Empty

Brochure

UVA+B model 501 radiometer brochure.

Internet Data Link Software

USB-RS232 Driver Software

UV and Ozone Measurements

UV and Ozone Measurements provide Meteorological Data (34Kb).

Ultraviolet radiation as applied to photoclimatherapy at the Dead Sea

A.I. Kudish, PhD, D. Abels, MD, and M. Harari, MD - International Journal of Dermatology 2003, 42, 359-365

Inter-comparison of the solar UVB, UVA and global radiation clearness and UV indices for Beer Sheva and Neve Zohar (Dead Sea), Isreal (259K)

A.I Kudish, V. Lyubansky, E.G. Evseev, A. Ianetz - Energy 30 (2005) 1623-1641

The Measurement and Analysis of Normal Incidence Solar UVB Radiation and Its Application to the Photoclimatherapy Protocol for Psoriasis at the Dead Sea, Israel

Avraham I. Kudish, Marco Harari and Efim G. Evseev - Photochemistry and Photobiology, 2011, 87: 215–222

The analysis of ultraviolet radiation in the Dead Sea basin, Isreal (126K)

A.I. Kudish, E. Evseev, A.P. Kushelesky - International Journal of Climatology, Vol.17 1697-1704 (1997)

Statistical relationships between solar UVB and UVA radiation and global radiation measurements at two sites in Isreal (165K)

A.I. Kudish, E. Evseev - International Journal of Climatology, Int. J. Climatol. 20: 759-770 (2000)

Statistical analysis and inter-comparison of the solar UVB, UVA and global radiation for Beer Sheva and Neve Zohar (Dead Sea), Isreal (256K)

A.I Kudish, V. Lyubansky, E.G. Evseev, A. Ianetz - Theor. Appl. Climatol. 80, 1-15 (2005)

Interfacing the 501 Biometer to a Campbell data logger (37Kb)

UV-Biometer - A Broad Band Instrument Complementing Ozone Measurement With Ground Based UV Exposure

Presented at Quadrennial Ozone Symposium Charlottesville, Virginia, USA June (1992) Daniel Berger, Marian Morys

Calibration of The Broad Band Radiometer

Describes 501 Radiometer calibration) Daniel Berger, Marian Morys

The Accurate Measurement of Biological Effective Ultraviolet Radiation

(135K) Paper was presented at the International Symposium on High Latitude Optics, Tromso, Norway, July 1993 Marian Morys, Daniel Berger

A Variable Sky-View Platform for the Measurement of Ultraviolet Radiation using the Model 501-UVA Radiometer

From Journal of Atmospheric and Oceanic Technology Vol. 20.

501 Digital Detector Cable

Solar Light Company offers cables for Digital 501 sensors with two connectors in various sizes such as 25' (7.6m), 50' (15.2m), 75'...

501 Analog Detector Cable

Solar Light Company offers cables for Analog 501 sensors with one connector in various sizes such as 25' (7.6m), 50' (15.2m), 75'...

SL-05721 NiCad Battery

Solar Light Company offers an industrial NiCad battery in size D.

Sensor Mounting Plate

Solar Light Company offers a sensor mounting plate for Model 501with 3 holes in the bottom to mount sensor...

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.