2.2" (5.7 cm) 300W Photobiology Solar Simulator Kit Model 16S-300-006 - Solarlight

2.2″ (5.7 cm) 300W Photobiology Solar Simulator Kit Model 16S-300-006

The 300W 16S-300-006 Photobiology Testing Solar Simulator Kits are designed for versatility in laboratory applications including photobiological studies, mutagenesis research, and UV biological experiments. The unit produces a 2.2″ (5.7 cm) Class A beam in the 290-400nm range, which can be quickly and easily configured by the user to provide UVA only, UVB only, UVA+B, or visible light optionally.

GET A QUOTE

Description

Our state of the art single output 16S-300-006 Photobiology Testing Solar Simulator Kits are designed for versatility in laboratory applications including photobiological studies, mutagenesis research, and UV biological experiments. They produce solar UV radiation in the 290-400nm range, and can be quickly and easily configured by the user to provide UVA only, UVB only, UVA+B, or visible light optionally. This feature allows an optional dimension of research to be used when studying carcinogenesis induced by UV radiation. The output intensity ranges from 500 to 700 J/m2 per minute, but can be tuned down to 1 J/m2 per minute. In the Ultraviolet configuration, the visible and infrared light is eliminated from its output. UV levels 20-30 times stronger than tropical sun can be produced without the thermal component associated with these high levels light, which allows testing to be accomplished without damaging the sample due to heat.

These precision research-grade instruments are specifically designed to comply with the latest laboratory standards such as ASTM, IEC, and ISO. Our Turnkey Photobiology Testing Kits include the Simulator, Dual-Input Data Logging PMA2100 Radiometer, NIST-traceable PMA-Series UVA, UVA+B, and Photopic Sensors, and many other accessories so you can start testing instantly!

 

 

Laboratory applications including photobiological studies, mutagenesis research, and UV biological experiments.

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (please specify at order)

This field can't be Empty

±5%

This field can't be Empty

Forced air

This field can't be Empty

11.8” (30 cm)

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Xenon Short Arc

This field can't be Empty

150W

This field can't be Empty

Near Zero

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

1.2” (3 cm)

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

Calibrated (Optional on all models)

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

3.9” (10 cm)

This field can't be Empty

7 lbs (3.2kg)

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

<ul> <li><a href="https://solarlight.com/product_category/solar-simulators/16s-series-uv-simulators/">16S-300-UV Solar Simulator with 2.2” (5.7 cm) vertical output</a></li> <li><a href="https://solarlight.com/model-xps-300-xenon-lamp-power-supply/">XPS-300 Power Supply</a></li> <li><a href="https://solarlight.com/product/datalogging-radiometer-pma2100-2/">PMA2100 Data Logging Radiometer Package</a></li> <li><a href="https://solarlight.com/product/pma-2107-non-weighted-uva-uvb-sensor/">PMA2107- UVS UVA+B Sensor</a></li> <li><a href="https://solarlight.com/product/pma-2110-uva-sensor/">PMA2110-UVS UVA Sensor</a></li> <li><a href="https://solarlight.com/product/pma2130-photopic-detector/">PMA2130 Photopic Sensor</a></li> <li>Visible Light Kit – to convert UV output to visible light output</li> <li>Heavy Duty Storage Case for conversion components</li> <li><a href="https://solarlight.com/product/sl-07702-dark-safety-glasses/">UV Safety Glasses (Dark)</a></li> </ul>

This field can't be Empty

2.2” (5.7 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 104°F / 0°C to +40°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

7 lbs (3.2 kg)

This field can't be Empty

Brochure

PHOTOBIOLOGY SOLAR SIMULATOR 16S-300-006 

Quick Start Guide

16S-Series 150-300W Solar Simulator Quick Start Guide

Laboratory Scissor Jack

Solar Light Company's laboratory scissor jack has a 5.5” X 5.5” (14 cm X 14 cm) surface area and...

SL-07702 Dark Safety Glasses

Solar Light offers safety glasses in various styles to suit research and testing environments using solar simulators. These lightweight...

SL-03730 300 Watt Ozone-Free Short Arc Xenon Lamp

This OEM Xe Replacement Lamp is designed to work with current Solar Light Model 601 Multiport® SPF Testing Solar...

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.