Laser sensor

Model PMA1142 Analog Laser Sensor

Solar Light’s Model PMA1142 Digital Laser Sensor is available in two full scale power levels of 10 watts (Model PMA1142-10,) and 40 watts (Model PMA 1142-40.) PMA1142-10 has an active area of 3.14 cm2, and the PMA1142-40 has an active area of 4.91 cm2.

Category:

Description

Solar Light’s Model PMA1142 Digital Laser Sensor is available in two full scale power levels of 10 watts (Model PMA1142-10,) and 40 watts (Model PMA 1142-40.) PMA1142-10 has an active area of 3.14 cm2, and the PMA1142-40 has an active area of 4.91 cm2. Display resolution is 1mW for the 10 watt model and 10mW for the 40 watt model. Each of these sensors includes an adjustable instrument base for accurate, stable placement.

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

Brochure

INFRARED AND FULL SPECTRUM SENSOR PMA1142 Full Spectrum Laser Power Detector

Interfacing PMA detectors to a Campbell data logger

PMA Series capabilities and applications

SL-07111 Sensor Extension Cable

Solar Light Company offers a sensor extension cable that is 2 meters (6.56 feet) and complete with female connector...

Placeholder

Underwater Cable

Solar Light Company offers an underwater cable with a 100 meter depth.

SL-07114 Cable Extension

Solar Light Company offers a cable Extension that is 10 meters (32.8 feet) and complete with female/male connector.

Hard Carrying Case with Storage

Solar Light Company offers a hard carrying case with storage for a meter and 2 sensors.

Placeholder

PMA2001-15 Sensor Extension Cable

Solar Light Company offers a 15 foot sensor extension cable complete with connectors for 5 wire sensors.

PMA2003 Sensor Bracket Tripod Mount

Solar Light Company offers a sensor bracket tripod mount.

Placeholder

18″ Long Probe Option

Solar Light Company offers an 18" long probe option.

SL-06465 Sensor Extension Cable

Solar Light Company offers a sensor extension cable that is 10 meters (32.8 feet) and complete with female connector...

SL-07116 Sensor Extension Cable

Solar Light Company offers a sensor extension cable that is 10 meters (32.8 feet), and complete with female/male connectors.

Placeholder

PMA2002 Sensor Bracket

Solar Light Company offers a sensor bracket that holds two detectors and is 1/4-20 threads.

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.