Light Testing Shelf LTS100, LTS200 and LTS300

Light Testing Shelf – Models LTS100, LTS200, LTS300 and LTS400

Converts any standard ICH Stability Testing Enclosure into a fully validated Photostability Chamber in minutes!

GET A QUOTE

Description

Convert your Stability Chambers into fully specified and validated Photostability Chambers in minutes, using Solar Light’s innovative LTS-Series Photostability Shelves. These units are built to ensure long life and reliable performance, utilizing corrosion-resistant brushed aluminum construction painted with a highly reflective internal coating for high uniformity across a greater shelf area. Fully compatible with  ICH Q1B options 1 & 2, the LTS Shelves slide into your existing chamber where it is conditioned, and then operate as self contained photostability units. You can convert all or just a part of your chamber by varying the number of shelves you install, increasing throughput and efficiency of your lab.

SHELF CONFIGURATIONS
LTS100 Series
LTS100-UV Light shelf with UV lamps, on/off switch. Temperature range 10-60°C
LTS100-VIS Light shelf with VIS lamps, on/off switch. Temperature range 10-60°C
LTS100-D65 Light shelf with D65 lamps, on/off switch. Temperature range 10-60°C
LTS200 Series
LTS200-UV Light shelf with UV lamps, DCS-2 dose controller with UV sensor. Temperature range 10-60°C
LTS200-VIS Light shelf with VIS lamps, DCS-2 dose controller with VIS sensor. Temperature range 10-60°C
LTS200-D65 Light shelf with D65 lamps, DCS-2 dose controller with UVA and VIS sensors. Temperature range 10-60°C
LTS300 Series
LTS300-UV Light shelf with UV lamps, Watlow controller for constant steady state exposure. Temperature range 10-60°C
LTS300-VIS Light shelf with VIS lamps, Watlow controller for constant steady state exposure. Temperature range 10-60°C
LTS300-D65 Light shelf with D65 lamps, Watlow controller for constant steady state exposure. Temperature range 10-60°C
LTS400 Series
LTS400-UV Light shelf with UV lamps, Watlow controller for constant steady state exposure, DCS-2 dose controller with UV
sensor.Temperature range 10-60°C
LTS400-VIS Light shelf with VIS lamps, Watlow controller for constant steady state exposure, DCS-2 dose controller with VIS sensor.Temperature range 10-60°C
LTS400-D65 Light shelf with D65 lamps, Watlow controller for constant steady state exposure, DCS-2 dose controller with UV and VIS sensors.Temperature range 10-60°C

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

160 lbs (72 kg)

This field can't be Empty

<ul> <li><strong>LTS100 Series:</strong> Light Testing Shelf with on/off control</li> <li><strong>LTS200 Series:</strong> Light Testing Shelf with DCS 2.0 dose controller and sensor </li> <li><strong>LTS300 Series:</strong> Light Testing Shelf with Watlow controller for constant steady state exposure </li> <li><strong>LTS400 Series:</strong> Light Testing Shelf with Watlow controller for constant steady state exposure and DCS 2.0 dose controller and sensor </li> </ul>

This field can't be Empty

20.0 x 30.0 x 26.0” <br> (50.8 x 76.20 x 66.04 cm)

This field can't be Empty

120VAC <br> 1 Ph 50/60 Hz

This field can't be Empty

Brochure

Light Testing Shelf – Models LTS100, LTS200, LTS300 and LTS400

User Manual

Light Testing Shelf User Manual

Placeholder

VIS Lamps For Light Testing Shelves

Solar Light Company offer VIS Lamps For Light Testing Shelves.

Placeholder

ID65 Lamps For Light Testing Shelves

Solar Light Company offers ID65 Lamps For Light Testing Shelves.

Placeholder

UV Lamps For Light Testing Shelves

Solar Light Company offers UV Lamps for Light Testing Shelves.

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.