Spectral Transmission Test | UV, VIS, and IR Spectral Transmission Testing

UVC, UVB, UVA, UVA+B, VIS, and IR Spectral Transmission Tests Using Monochromator

Solar Light Company, LLC can provide accurate spectral transmission analysis of materials in multiple spectra for any testing requirement including UV, VIS, and IR. Using advanced spectroradiometers, monochromators, NIST traceable standard lamps, and NIST Traceable sensors, we can provide absolute spectroradiometric analyses with optional detailed reports, showing sample performance under strict parameters.

  • Spectral Transmission of a Material. Typical scans include:
  • UV 250-400nm in 5nm intervals
  • UV+VIS 250-800nm in 5nm intervals
  • IR 800-1800nm in 5nm intervals
  • Sunlight applications 280-1100nm in 10nm intervals
  • UV+VIS+IR 250-1600nm available in 1nm intervals
  • Includes data and chart
  • Contact us for any special requirements

ADDITIONAL SAMPLES

Each Additional Sample $220

SPECTRAL TRANSMISSION REPORT

Optional for all tests

RETURN SAMPLES?

If you want your samples mailed back upon completion, select Yes. There will be a $25 handling fee added and you will be able to ship via your UPS or Fedex account at checkout.

GET A QUOTE

Description

Typical Material Spectral Transmission Tests include:

  • UVA, UVB, and UVC Range: Tested at 250nm-400nm in 1nm steps
  • Visible Range: Tested at 400nm-700nm in 10nm steps
  • Double Monochromator: UVC, UVA, UVB, UVA+B, Visible and IR from 250 nm to 1800 nm.
  • Under a wide variety of possible illuminants:
    • Illuminant A, B, C, D65
    • ACD65, Fcw, TL84, Ultralume
    • D50, D60, D75, F02, F07, F11, ILA, and ILC

Typical materials tested include:

Awning fabrics
Have your awning materials tested for spectral transmission of solar light to ensure they do not transmit high levels of harmful wavelengths. Testing for UVA, UVB, UVA+B and visible ranges are available.

Garment fabrics
We can expose fabrics used for outdoors to measure the amount of radiation that is allowed to pass through by the particular material.

Display cases
Spectral transmission through the glass or plastic covers of display cases and cabinets is measured to assess the amount of radiation that may reach the exhibits enclosed, and assess the potential risks of fading or other damage that may be caused as a result.

Optical Filters
Have your optical filters measured to ensure that they are performing properly, and that they are blocking or transmitting the spectrum within specification.

Medical Packaging
Test your medical packaging materials for the effects of spectral radiation when stored on shelves under artificial light, or from natural sunlight passing through windows.

Manual Ordering:

To send Materials and Equipment to Solar Light Company for Testing:

1. Complete the necessary form for “SPECTRAL TRANSMISSION TESTING” and mark box “Attn: Materials Testing Laboratory”.

2. Issue a purchase order or include payment information.

3. Provide specific shipping instructions for the return shipment if applicable, and email PO with Return Form to Solar Light Company

4. Enclose a copy of the completed form in the package with the sample(s).

Ship prepaid via UPS or FedEx, fully insured to:

Solar Light Company, LLC
Attn: Materials Testing Laboratory
100 East Glenside Avenue
Glenside, PA. 19038 USA

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

<p><strong>Include, but are not limited to:</strong></p> <ul> <li>ASTM G 151 – 97 “Standard Practice for Exposing nonmetallic materials in accelerated test devices that use laboratory light sources”</li> <li>ASTM G-155-05a “Standard practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials”</li> <li>ASTM D 2565 – 99 “Standard practice for Xenon-Arc exposure of plastics intended for outdoor applications”</li> <li>ASTM D 4459 – 99 “Standard practice for Xenon-Arc exposure of plastics intended for indoor applications”</li> <li>ASTM D5071 – 06 “Standard Practice for Exposure of Photodegradable Plastics in a Xenon Arc Apparatus”</li> <li>ASTM D4329 – 05 “Standard Practice for Fluorescent UV Exposure of Plastics”</li> <li>ASTM D5208-09 “Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics”</li> <li>ASTM D 4674 – 89 “Standard test method for accelerated testing for color stability of plastics exposed to indoor fluorescent lighting and window-filtered daylight”</li> <li>ASTM D3424 − 11 “Standard Practice for Evaluating the Relative Lightfastness and Weatherability of Printed Matter”</li> <li>ASTM D4303-03 “Standard Test Methods for Light fastness of Colorants Used in artists’ materials”</li> <li>ASTM D4587-11 “Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings”</li> <li>ASTM D750- 06 “Standard Test Method for Rubber Deterioration Using Artificial Weathering Apparatus”</li> <li>ASTM D6695 – 08 “Standard Practice for Xenon-Arc Exposures of Paint and Related Coatings”</li> <li>ASTM G147 “Standard Practice for Conditioning and Handling of Nonmetallic Materials for Natural and Artificial Weathering Tests”</li> <li>ASTM ISO 4892-2 “Plastics – Methods of exposure to laboratory light sources – Part 2 Xenon arc  sources”</li> <li>ASTM ISO 4892-3 “Plastics – Methods of exposure to laboratory light sources – Part 3 Fluorescent UV lamps”</li> <li>ASTM ISO 11341 “Paints and varnishes – Artificial weathering and exposure to artificial radiation – Exposure to filtered xenon-arc radiation”</li> <li>ASTM BS EN ISO 105-B02:1999 “Color fastness to artificial light: Xenon arc fading lamp test”</li><li>ASTM D6695 − 16 Standard Practice for Xenon-Arc Exposures of Paint and Related Coatings</li></ul> <p><strong>Color test standards</strong></p> <ul> <li>ASTM E308-08 “Computing the colors of objects using the CIE system”</li> <li>ASTM E313-05 “Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured COLOR Coordinates (Abstract only)”</li> <li>ASTM E1347 – 06 “Standard Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry”</li> <li>ASTM D1729 “Practice for Visual Appraisal of Colors and Color Differences of Diffusely-Illuminated Opaque Materials”</li> <li>ASTM D6290-13 “Standard Test Method for Color Determination of Plastic Pellets UV Exposure Tests”</li> </ul> <p> <strong>UPF Standards</strong></p> <ul> <li>AATCC TM183-2010 “Transmittance or Blocking of Erythemally Weighted Ultraviolet Radiation through Fabrics”</li> <li>ASTM D6544 “UPF Standard Practice for Preparation of Textiles Prior to Ultraviolet (UV) Transmission Testing”</li> <li>ASTM D6603 “Standard Specification for Labeling of UV-Protective Textiles1″</li> <li>AS_NZS_4399 “Sun protective clothing— Evaluation and classification”</li> <li>BS EN 13758-1 “Textiles – Solar UV protective properties – Method of test for apparel fabrics”</li> <li>GBT18830-2009 “Textiles – Evaluation for solar ultraviolet protective properties”</li><li>ISO 12312-2:2015 Eye and face protection - Sunglasses and related eyewear - Part 2: Filters for direct observation of the sun (ISO 12312-2:2015)</li> </ul>

This field can't be Empty

Accelerated UV Test Examples

3-D Printed bracelet
ADA safety flooring
Advertising placard ink process
Aircraft fuel cap
Anodized Motorcycle parts
Arc lamp housing coatings
Auto headlamp coatings
Auto wear indicator label
Baseball bat coating
Cartridge fuse printing ink
Chemical sorbent materials
Clear plastic housings
Clear plastic panels
Coated galvanized roofing
Coated hydraulic lines
Coated textiles
Coatings on Inks
Colored anodize samples
Colored sand
Colored textiles
Control panel housing
Custom paint colors
Diffuse display glass
Electric power transformer cowling
Electrical cable joint materials
Electronic LCDs
Emergency Lighting Lenses
Engine fuel fitting
Extraterrestrial mission components
Extraterrestrial reflective materials
Extruded HDPE
Extruded PVC knob
Fabric samples
Fiberglass structural cable
Filament dyed acrylic polyester
Filled polymer materials
Fire extinguisher labels
Flow meter housing
Garden plant potting accessories
Gardening material packaging
Glass – polymer adhesive
Glass block adhesive
Glass coatings
Hearing Aid Battery housings
High stress loading fiberglass material
High voltage insulators
Hiking tent fabric
Household consumer product packaging
Ink jet printer ink
Ink on stick on labels
Lamp anodize coating @ 65°C
LED housings
Lighting fixture parts
Logo Display Coating
Membrane switch panel
Microwave receiver housing
Molded graphite composite
Motorcycle gear anodize
Non stabilized polypropylene
Optical scanner window
Outdoor camouflage fabric
Outdoor decals
Outdoor electrical connectors
Outdoor fabric
Outdoor hose cover
Outdoor Safety Labels
Outdoor security electronics housings
Outdoor wireless housing
PEET sample
Photographic paper protective spray
Photovoltaic device coatings
Plastic Cap at 120°F
Plastic plant pots
Playground structure materials
Pool filter cover gasket
Potting material
Power cord and camera case
Price tag holders
Protective window film
PVC handles
Reflective safety placard
Resin laminate on glass
Rubber floor tiles
Safety Label on metal casting
Safety ramp tiles
Satellite dish housing materials
Shopping cart display inks
Silicone to fabric adhesion
Silk flowers
Simulated wood laminate
Solar battery charging housing
Solar Fresnel lenses
Solar mirrors
Solenoid housing
Sprinkler cover
Sunglass frames’ adhesive
Touch screen panels
Touch screen polymer
Touch screen polymer film
TPX plastics
UPC labels
Urethane samples
UV stabilized PE handles
Water meter bezel
Watercraft housing
Webcam housing
Wicker outdoor furniture
Window frame and sash
Windscreen
Woven tent straps
Yellow ink on plastic

Accelerated Indoor Fluorescent UV Test Examples

Casket fabrics
Catheter pouch
Catheter pouch parts
Chemical container labels
Chewing gum packaging
Clear Plastic Display Frame
Display case Polycarbonate
Fluorescent lamp housing
Fluorescent lighting cover
Infant food packaging
Ink images on Paper labels
LDPE colored test panels
Medical device housings
Medical Packaging
Medical tubes
Molded, colored plastic panels
Office wall fiber materials
Polymer tubes
Retail Display housing
Scented candles ’ color change
Shaving razor packaging
Surgery towel packaging

UV – Visible Transmission and Reflection Test Examples

Catheter pouch UV transmission
Fluorescent emission of a label under UV
Fluorescent lamp irradiance(Several)Germicidal oral therapy lamp (Several)
Germicidal Lamp (Several)
Infant bilirubin therapy eye protection
LCD display color change transmission / exposure
Mercury Xenon Lamp
NIR Spectral transmission of Plastic filters
Performance sunglasses transmission / exposure
Safety analysis of a UV light source
Solar Admittance of a Radome panel
Solar Fresnel lens transmission / exposure
Solar liquid & tube material transmission / exposure
Spectral irradiance of Bilirubin light sourceBlack light UVA spectral irradiance
Spectral irradiance of IR lamps (Several)
Spectral irradiance of UV lamp
Spectral irradiance of UV LED
Spectral irradiance of UV resistant tubing
Spectral irradiance of UVB detector
Spectral irradiance of Vis LED headgear
Spectral transmission of Amber glass bottles
Spectral transmission of Colored fabric
Spectral transmission of Epoxy dispenser tips
Spectral transmission of Food Container
Spectral transmission of Food storage glassware
Spectral transmission of Loudspeaker fabric
Spectral transmission of PV cell panel materials
Spectral transmission of shrink wrap material
Spectral transmission of UV transmitting polymer
Spectral transmission of Zip-Lock bag material
Touch Screen Solar transmission / exposure
UV photodiode irradiance (Several)
UV reptile Lamps Irradiance (Several)

Accelerated Outdoor Fluorescent UV Test Examples

Automotive Canopy Window
ABS Cellphone cases
Automotive window decals
Electrical control housing
Fire Extinguisher cylinder paint
Inflatable solar emergency lighting
Strip light LED packaging
Wall and floor tiles

Accelerated UVC Test Examples

Electrical sheath for Interior of Germicidal Exposure Chamber
Protective Eyewear Lenses

Test and Measurement Equipment

Light Sources
Solar Light Model 16S-150-003 Short Arc Xenon UV Solar Simulators
Solar Light Model 16S-300-003 Short Arc Xenon UV Solar Simulators

UVA Fluorescent lamps
UVA+B Fluorescent lamps
UVC Fluorescent lamps
High Intensity Visible Fluorescent lamps

Solar Light Model LS-1000 6″ Air Mass
Solar Light Model LS-1000 6″ UV Solar Simulator

Instrumentation
Solar Light Model PMA2100 dual channel data-logging radiometer
Solar Light Model PMA2107 UVA+B Sensors
Solar Light Model PMA2110 UVA Sensors
Solar Light Model PMA2144 Class II Pyranometer

X-rite Color Eye 7000A Spectrophotometer

Optronic Laboratories Model 750 Double Grating Monochromator System
Optronic Laboratories Model 740 A/D Double Grating Monochromator
Optronic Laboratories Model 730A Radiometer
Optronic Laboratories Model 740-1C Controller
Optronic Laboratories Model OL 220M Quartz-halogen lamp
Optronic Laboratories Model 65DS Precision Current Source

Solar Light 290SPF UV Transmission Analyzer

Controlled Environmental Test Equipment
Stability Environments Controlled Temperature, Humidity & Light Walk-in Chamber
Stability Environments 33 cu ft Controlled Temperature & Humidity Reach-in Chamber
Tenny Environmental Chamber