UVB sensor

Model PMA2105 Digital UVB Sensor With Beam Splitter Adapter

Solar Light’s Model PMA2105 Digital Biologically Weighted Erythema UV Sensor With Beam Splitter Adapter allows direct coupling with the beam splitter on the subject stop available for our legacy 15S-Series and modern 16S-Series Solar Simulators. The sensor’s spectral response closely follows the Erythema Action Spectrum.

Category:

Description

Solar Light’s Model PMA2105 Digital Biologically Weighted Erythema UV Sensor With Beam Splitter Adapter allows direct coupling with the beam splitter on the subjuect stop available for our legacy 15S-Series and modern 16S-Series Solar Simulators. The sensor’s spectral response closely follows the Erythema Action Spectrum.  A built-in Teflon diffuser assures that the sensor has negligible azimuthal error, making the measurement insensitive to the rotation of the sensor. Extended measurement range of 600 [MED/Hr] enables measurement of intense radiation. This sensor enables our PMA-Series Radiometers to operate as smart dose controllers/monitors, substantially enhancing the functionality of the Solar Simulators. The MED Calculation Formula (1 [MED/Hr] = 5.833 [µW/cm2]) is programmed into the PMA2105 Sensor, allowing for easy conversion of units. Consequently, the integrated effective dose can be expressed in [mJoules/cm2] or MED. The measurement result can be shown in [MED/Hr], [µW/cm2] as well as a time to accumulate 1 [MED]. High dynamic range of the sensor allows measurements down to 1 [µW/cm2] with the ability to measure radiation as strong as 3.5 [mW/cm2].

0.4” (1 cm)

This field can't be Empty

Vertical Downward, Vertical Upward, or Horizontal (for all models - please specify at order)

This field can't be Empty

Xenon Short Arc (For All Models)

This field can't be Empty

150W (For All Models)

This field can't be Empty

±5% (For All Models)

This field can't be Empty

A (IEC 60904-9 2007)<br> A (JIS C 8912)<br> A (ASTM E927 - 05)

This field can't be Empty

< ±2% rms

This field can't be Empty

B (IEC 60904-9 2007)<br> B (JIS C 8912)<br> B (ASTM E927 - 05)

This field can't be Empty

3” (7.6 cm)

This field can't be Empty

n/a

This field can't be Empty

Near Zero

This field can't be Empty

Factory Set Limit is 150 watts max

This field can't be Empty

32°F to 95°F / 0°C to 35°C

This field can't be Empty

-4°F to 185°F / -20°C to +85°C

This field can't be Empty

0 to 95% non-condensing

This field can't be Empty

Forced air

This field can't be Empty

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

This field can't be Empty

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

This field can't be Empty

7.1 oz. (200 grams)

This field can't be Empty

<img src="https://solarlight.com/wp-content/uploads/PMA2105.jpg"><border="0">

This field can't be Empty

<img src="https://solarlight.com/wp-content/uploads/PMA2105-log-e1509130467200.jpg"><border="0">

This field can't be Empty

600 [MED/Hr], 10 [MED/min], 3,500 [µW/cm²], 6 [sec-10 Hrs]

This field can't be Empty

0.02 [MED/Hr], 0.001 [MED/min], 0.1 [µW/cm²], 1 [hh:mm:ss]

This field can't be Empty

32 to 120°F (0 to +50°C)

This field can't be Empty

1% /°C for Solar Radiation,

This field can't be Empty

5ft (1.5m)

This field can't be Empty

1.6" (40.6 mm)

This field can't be Empty

Brochure

UVB SENSOR PMA2105 with beam splitter

Interfacing PMA detectors to a Campbell data logger

PMA Series capabilities and applications 

Product Not Found

1 YEAR STANDARD WARRANTY

SOLAR LIGHT COMPANY warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  SOLAR LIGHT COMPANY warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of SOLAR LIGHT COMPANY. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized SOLAR LIGHT COMPANY representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with SOLAR LIGHT COMPANY’s operating instructions, maintenance instructions and specifications. Utilization of only SOLAR LIGHT COMPANY’s authorized parts and components.  The utilization of a duly authorized representative for all work performed on SOLAR LIGHT COMPANY equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by SOLAR LIGHT COMPANY and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SOLAR LIGHT COMPANY BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.