-
6″ (15 cm) Round Beam 1000W HEV Solar Simulator Model LS1000-6R-HEV
LS1000-6R-HEV Solar Simulators produce a 6″ (15 cm) High Energy Visible (HEV) solar radiation in the 400-500nm range, or the portion of the visible light spectrum that is closest to the UV band (mainly violet and blue light rays), specifically designed for in vitro and in vivo sunscreen testing, as well as clinical, medical, and photobiological studies.
-
6″ (15 cm) Round Beam 1000W IR Solar Simulator Model LS1000-6R-IR
LS1000-6R-IR Solar Simulators produce a 6″ (15 cm) Infrared (IR) solar radiation in the 700-2400nm range specifically designed for in vitro and in vivo sunscreen testing, as well as clinical, medical, and photobiological studies.
-
6″ (15 cm) Round Beam 1000W UVA Solar Simulator Model LS1000-6R-UVA
Solar Light’s state of the art single output 1000W LS1000-6R-UVA Solar Simulator produces a 6” (15 cm) UVA beam in the range of 320-400 nm, specifically for research applications such as in vitro and in vivo sunscreen testing.
-
6″ (15 cm) Round Beam 1000W UVB Solar Simulator Model LS1000-6R-UVB
LS1000-6R-UVB Solar Simulators produce a 6″ (15 cm) UVB spectrum in the range of 280-320 nm, which can be used for a wide variety of dermatological research such a photo allergy and photo toxicity studies.
-
Light Testing Shelf – Models LTS100, LTS200, LTS300 and LTS400
Converts any standard ICH Stability Testing Enclosure into a fully validated Photostability Chamber in minutes!
-
Model 521 Microtops II® Ozonometer
Solar Light’s Model 521 Microtops II® is a 5 channel hand-held ozonometer for measuring total ozone column per standard WMO configuration easily, accurately and dependably.
-
Model PMA2101 Digital Biologically-Weighted Erythema UVB Sensor
Solar Light’s Model PMA2101 Digital Biologically-Weighted Erythema UVB Sensor provides an accurate measurement of SUV radiation (also known as “sunburning UV”) from sunlight or artificial light sources.
-
Model PMA2110 Digital UVA Sensor
Solar Light’s Model PMA2110 Digital UVA Sensor provides fast and accurate irradiance measurement in the UVA region, with spectral response in the 320nm to 400nm range. This sensor is ideal for laboratory applications measuring mercury, xenon, metal halide, or fluorescent lamps (commonly used for UVA studies,) as well as sunlight.
-
Model PMA2200 Single-Input Radiometer
Solar Light’s versatile Model PMA2200 Single-Input Radiometer accepts over 85 different PMA-Series sensors measuring UV, Visible and IR wavelengths.
-
Model SL-3201 Tanning Bed Meter
Solar Light’s Model SL-3201 Tanning Bed Meter displays the intensity of SUV – Sunburning UV in Minimal Erythemal Doses per Hour (MED/Hr,) the accepted clinical measure for sunburn potential. A UVC sensor measures light intensity in the 275-285 nm range, and displays UVC irradiance in mW/cm2.
-
Model XPS-300 Xenon Lamp Power Supply
Solar Light’s Model XPS-300 Power Supply is a highly stable current source for xenon short arc lamps which is specifically designed to work with Solar Light’s 601-Series and 16S-Series Solar Simulator models, with universal mains operation from 90-250VAC.
-
Sensors – Calibration Service
Solar Light Company, LLC recommends our annual NIST Traceable Calibration Service for our products to maintain optimal performance. Meters and sensors should be calibrated annually, and light sources should be cleaned and aligned annually. Standard turnaround time is 7-10 days from receipt.
-
SL-07702 Dark Safety Glasses
Solar Light offers safety glasses in various styles to suit research and testing environments using solar simulators. These lightweight Dark glasses feature ratchet temples, combined with non-slip rubber head grips, to allow a customized fit for virtually any head size. The lenses are constructed of impact-resistant polycarbonate which offers outstanding protection against harmful UV rays and compliance to ANSI eye wear standards.
-
UW254 Underwater Germicidal Detector
Solar Light’s Model UW254 Underwater Germicidal Lamp Monitor is specifically designed to continuously monitor UV intensity from UVC lamps in waste water treatment plants. The sensor provides an indication of the effectiveness of the lamps as they age because it is sensitive to the sterilizing UVC wavelengths of mercury lamps at 253.7nm. The sensor reliably interfaces with the Solar Light GLM100 germicidal lamp monitor, or your choice of monitor or data acquisition equipment.
-
1.2” (3 cm) 300W Air Mass Solar Simulator Model 16S-300-1.2-AM
Solar Light’s 300W single output 16S-300-1.2-AM Solar produces a 1.2″ (3 cm) spot beam Class A Air Mass 0 and Air Mass 1.5 Emission Spectra to accurately replicate full spectrum sunlight, with 1 sun output intensity and over 90% uniformity in the usable area. The output can be quickly and easily configured by the user to provide UVA only, UVB only, UVA+B, or full spectrum sunlight optionally. These precision research-grade instruments are specifically designed to comply with the latest laboratory standards such as ASTM, IEC, and ISO.